Boiler Water Treatment Principles and Practice:  Charts and Notes for Field Use

دانلود کتاب Boiler Water Treatment Principles and Practice: Charts and Notes for Field Use

Author: Colin Frayne

0 (0)

توضیحات کتاب :

Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program

سرچ در وردکت | سرچ در گودریدز | سرچ در اب بوکز | سرچ در آمازون | سرچ در گوگل بوک

1,185 بازدید 0 خرید

ضمانت بازگشت

ضمانت بازگشت

فایل های تست شده

فایل های تست شده

پرداخت آنلاین

پرداخت آنلاین

تضمین کیفیت

تضمین کیفیت

دانلود فوری

دانلود فوری

Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program. BW Carbonate Reserve Requirements by Pressure and Sulfate Concentration - Carbonate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard or Partially Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated WT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Chelant demand (ppm product) per 1ppm substrate EDTA Chelant or All-Polymer/All-Organic Program. Recommended BW Control Limits for Fired WT Boilers Employing Demineralized or Similar Quality FW - Oxygen Solubility at Atmospheric Pressure - Properties of Oxygen Scavengers - Carbon Dioxide Evolution from FW Alkalinity - Amine Requirement to Reach a Stable Condensate pH - Amine Basicity Dissociation Constants - Neutralizing Amine Summary Notes - Some DR values for CO2, NH3 and neutralizing amines at various pressures - Calculating Alkalinity Feed-Rate Requirements - [ASME Consensus table 1: Suggested water chemistry limits. Industrial watertube, high duty, primary fuel fired, drum typeMakeup water percentage: Up to 100% of feedwater. Conditions: Includes superheater, turbine drives or process restriction on steam purity] - [ASME Consensus table 2: Suggested chemistry limits. Industrial watertube, high duty, primary fuel fired, drum type] - [ASME Consensus table 3: Suggested chemistry limits. Industrial firetube, high duty, primary fuel fired] - [ASME Consensus table 4: Suggested water chemistry limits. Industrial coil type, watertube, high duty, primary fuel fired rapid steam generators] - [ASME Consensus table 5: Suggested water chemistry limits. Marine propulsion, watertube, oil fired drum type] - [ASME Consensus table 6: Suggested water chemistry limits. Electrode, high voltage, forced circulation jet type] - Notes

چکیده فارسی

فهرست مطالب: درباره نویسنده - دمای بخار اشباع شده در فشارهای مختلف دیگ - واحدهای انرژی و نیرو بویلر - مقادیر گرمایش ناخالص معمولی سوخت‌ها (بر اساس تقریباً 80 درصد راندمان سوخت به بخار) - مصرف انرژی و رتبه‌بندی‌های خروجی معمولی برای دیگ بخار لوله آتش - جداول بخار مناسب برای هواگیرهای فشار - محاسبه ضریب هدایت حرارتی برای برخی از فلزات مبدل حرارتی و رسوبات دیگ - انواع آب یا بخار که معمولاً در اکثر نیروگاه های گرمایشی و تولید بخار استفاده می شود - مواد معدنی رایج در منابع آب طبیعی MU - مشکلات خاص کنار آب / کنار بخار که روی کارخانه‌های دیگ بخار MPHW و HPHW تأثیر می‌گذارد - شاخص‌های غلظت نمک - خلاصه مشکلات کنار آب / کنار بخار مؤثر بر تاسیسات دیگ بخار LPHW و LP - آلودگی FW از آب MU - آلودگی FW از میعانات برگشتی - مشکلات با ترکیب نهایی FW - رسوب سطوح کنار آب بخش بویلر توسط قلیایی نمک های فلزی زمین، سایر نمک های معدنی و مواد آلی - فلس ها و رسوبات کریستالی سیلیکا و سیلیکات موثر بر سطوح کنار آب بخش دیگ بخار - اکسید آهن و سایر رسوبات خوردگی بخش دیگ بخار - مشکلات خوردگی بخش دیگ بخار که شامل اکسیژن، سلول های غلظت و pH پایین است - استرس و بالا خوردگی مربوط به دما - خلوص بخار، کیفیت و سایر مشکلات عملیاتی - مشخصات درجات آب با کیفیت بالا مناسب برای دیگهای بخار WT با فشار بالاتر - ملاحظات عملی برای نرم کننده تبادل یونی RW - انواع برنامه تصفیه داخلی - محاسبات مورد نیاز چرخه کربنات - فسفات -محاسبات مورد نیاز چرخه - راهنمای باقیمانده های تانن در BW - برنامه چرخه کربنات. الزامات ذخیره کربنات BW بر اساس فشار و غلظت سولفات - برنامه انعقاد و بارش چرخه کربنات. محدودیت‌های کنترل BW توصیه‌شده برای بویلرهای FT غیر دارای رتبه بالا که از FW سخت یا نیمه نرم شده استفاده می‌کنند - برنامه انعقاد و بارش چرخه فسفات. محدودیت‌های کنترل BW توصیه‌شده برای دیگ‌های FT بدون رتبه بالا که از FW سخت، نیمه نرم شده یا کاملاً نرم شده استفاده می‌کنند - برنامه انعقاد و بارش چرخه فسفات. محدودیت‌های توصیه‌شده کنترل BW برای دیگ‌های WT با رتبه بالا که از FW سخت، جزئی نرم شده یا کاملاً نرم استفاده می‌کنند - تقاضای کلانت (محصول ppm) به ازای هر ppm 1 بستر EDTA Chelant یا برنامه تمام پلیمری/تمام آلی. محدودیت های توصیه شده کنترل BW برای بویلرهای WT سوختنی که از FW غیر معدنی یا کیفیت مشابه استفاده می کنند - حلالیت اکسیژن در فشار اتمسفر - ویژگی های حذف کننده های اکسیژن - تکامل دی اکسید کربن از قلیایی FW - نیاز به آمین برای رسیدن به یک غلظت پایدار در آمیختگی آمین - غلظت های غیر اجتماعی پایدار یادداشت ها - برخی از مقادیر DR برای CO2، NH3 و آمین های خنثی کننده در فشارهای مختلف - محاسبه نیازهای نرخ تغذیه قلیایی - [جدول اجماع ASME 1: محدودیت های پیشنهادی شیمی آب. لوله آب صنعتی، کارکرد بالا، سوخت اولیه، نوع درام درصد آب آرایشی: تا 100 درصد آب تغذیه. شرایط: شامل سوپرهیتر، درایوهای توربین یا محدودیت فرآیند در خلوص بخار می‌شود] - [جدول اجماع ASME 2: محدودیت‌های پیشنهادی شیمی. لوله آب صنعتی، کارکرد بالا، سوخت اولیه، نوع درام] - [جدول اجماع ASME 3: محدودیت های پیشنهادی شیمی. فایرتیوب صنعتی، کارکرد بالا، سوخت اولیه] - [جدول اجماع ASME 4: حدهای پیشنهادی شیمی آب. مولدهای بخار سریع نوع کویل صنعتی، لوله آب، کارکرد بالا، سوخت اولیه] - [جدول 5 اجماع ASME: محدودیت‌های پیشنهادی شیمی آب. نیروی محرکه دریایی، لوله آبی، نوع درام نفت سوز] - [جدول توافق ASME 6: محدودیت های پیشنهادی شیمی آب. الکترود، ولتاژ بالا، نوع جت گردش اجباری] - یادداشت ها

ادامه ...

Ebook details:
عنوان: Boiler Water Treatment Principles and Practice: Charts and Notes for Field Use
نویسنده: Colin Frayne
ناشر: Chemical Publishing Company (July 3, 2013)
زبان: English
شابک: 082060173X, 978-0820601731
حجم: 1 Mb
فرمت: True Pdf

ادامه ...

ادامه ...
برای ارسال نظر لطفا وارد شوید یا ثبت نام کنید
ادامه ...
پشتیبانی محصول

۱- در صورت داشتن هرگونه مشکلی در پرداخت، لطفا با پشتیبانی تلگرام در ارتباط باشید.

۲- برای خرید محصولات لطفا به شماره محصول و عنوان دقت کنید.

۳- شما می توانید فایلها را روی نرم افزارهای مختلف اجرا کنید(هیچگونه کد یا قفلی روی فایلها وجود ندارد).

۴- بعد از خرید، محصول مورد نظر از صفحه محصول قابل دانلود خواهد بود همچنین به ایمیل شما ارسال می شود.

۵- در صورت وجود هر مشکلی در فرایند خرید با تماس بگیرید.