Boiler Water Treatment Principles and Practice:  Charts and Notes for Field Use

دانلود کتاب Boiler Water Treatment Principles and Practice: Charts and Notes for Field Use

Author: Colin Frayne

0 (0)

توضیحات کتاب :

Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program

سرچ در وردکت | سرچ در گودریدز | سرچ در اب بوکز | سرچ در آمازون | سرچ در گوگل بوک

1,697 بازدید

ضمانت بازگشت

ضمانت بازگشت

فایل های تست شده

فایل های تست شده

پرداخت آنلاین

پرداخت آنلاین

تضمین کیفیت

تضمین کیفیت

دانلود فوری

دانلود فوری

Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program. BW Carbonate Reserve Requirements by Pressure and Sulfate Concentration - Carbonate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard or Partially Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated WT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Chelant demand (ppm product) per 1ppm substrate EDTA Chelant or All-Polymer/All-Organic Program. Recommended BW Control Limits for Fired WT Boilers Employing Demineralized or Similar Quality FW - Oxygen Solubility at Atmospheric Pressure - Properties of Oxygen Scavengers - Carbon Dioxide Evolution from FW Alkalinity - Amine Requirement to Reach a Stable Condensate pH - Amine Basicity Dissociation Constants - Neutralizing Amine Summary Notes - Some DR values for CO2, NH3 and neutralizing amines at various pressures - Calculating Alkalinity Feed-Rate Requirements - [ASME Consensus table 1: Suggested water chemistry limits. Industrial watertube, high duty, primary fuel fired, drum typeMakeup water percentage: Up to 100% of feedwater. Conditions: Includes superheater, turbine drives or process restriction on steam purity] - [ASME Consensus table 2: Suggested chemistry limits. Industrial watertube, high duty, primary fuel fired, drum type] - [ASME Consensus table 3: Suggested chemistry limits. Industrial firetube, high duty, primary fuel fired] - [ASME Consensus table 4: Suggested water chemistry limits. Industrial coil type, watertube, high duty, primary fuel fired rapid steam generators] - [ASME Consensus table 5: Suggested water chemistry limits. Marine propulsion, watertube, oil fired drum type] - [ASME Consensus table 6: Suggested water chemistry limits. Electrode, high voltage, forced circulation jet type] - Notes

چکیده فارسی

فهرست مطالب: درباره نویسنده - دمای بخار اشباع شده در فشارهای مختلف دیگ - واحدهای انرژی و نیرو بویلر - مقادیر گرمایش ناخالص معمولی سوخت‌ها (بر اساس تقریباً 80 درصد راندمان سوخت به بخار) - مصرف انرژی و رتبه‌بندی‌های خروجی معمولی برای دیگ بخار لوله آتش - جداول بخار مناسب برای هواگیرهای فشار - محاسبه ضریب هدایت حرارتی برای برخی از فلزات مبدل حرارتی و رسوبات دیگ - انواع آب یا بخار که معمولاً در اکثر نیروگاه های گرمایشی و تولید بخار استفاده می شود - مواد معدنی رایج در منابع آب طبیعی MU - مشکلات خاص کنار آب / کنار بخار که روی کارخانه‌های دیگ بخار MPHW و HPHW تأثیر می‌گذارد - شاخص‌های غلظت نمک - خلاصه مشکلات کنار آب / کنار بخار مؤثر بر تاسیسات دیگ بخار LPHW و LP - آلودگی FW از آب MU - آلودگی FW از میعانات برگشتی - مشکلات با ترکیب نهایی FW - رسوب سطوح کنار آب بخش بویلر توسط قلیایی نمک های فلزی زمین، سایر نمک های معدنی و مواد آلی - فلس ها و رسوبات کریستالی سیلیکا و سیلیکات موثر بر سطوح کنار آب بخش دیگ بخار - اکسید آهن و سایر رسوبات خوردگی بخش دیگ بخار - مشکلات خوردگی بخش دیگ بخار که شامل اکسیژن، سلول های غلظت و pH پایین است - استرس و بالا خوردگی مربوط به دما - خلوص بخار، کیفیت و سایر مشکلات عملیاتی - مشخصات درجات آب با کیفیت بالا مناسب برای دیگهای بخار WT با فشار بالاتر - ملاحظات عملی برای نرم کننده تبادل یونی RW - انواع برنامه تصفیه داخلی - محاسبات مورد نیاز چرخه کربنات - فسفات -محاسبات مورد نیاز چرخه - راهنمای باقیمانده های تانن در BW - برنامه چرخه کربنات. الزامات ذخیره کربنات BW بر اساس فشار و غلظت سولفات - برنامه انعقاد و بارش چرخه کربنات. محدودیت‌های کنترل BW توصیه‌شده برای بویلرهای FT غیر دارای رتبه بالا که از FW سخت یا نیمه نرم شده استفاده می‌کنند - برنامه انعقاد و بارش چرخه فسفات. محدودیت‌های کنترل BW توصیه‌شده برای دیگ‌های FT بدون رتبه بالا که از FW سخت، نیمه نرم شده یا کاملاً نرم شده استفاده می‌کنند - برنامه انعقاد و بارش چرخه فسفات. محدودیت‌های توصیه‌شده کنترل BW برای دیگ‌های WT با رتبه بالا که از FW سخت، جزئی نرم شده یا کاملاً نرم استفاده می‌کنند - تقاضای کلانت (محصول ppm) به ازای هر ppm 1 بستر EDTA Chelant یا برنامه تمام پلیمری/تمام آلی. محدودیت های توصیه شده کنترل BW برای بویلرهای WT سوختنی که از FW غیر معدنی یا کیفیت مشابه استفاده می کنند - حلالیت اکسیژن در فشار اتمسفر - ویژگی های حذف کننده های اکسیژن - تکامل دی اکسید کربن از قلیایی FW - نیاز به آمین برای رسیدن به یک غلظت پایدار در آمیختگی آمین - غلظت های غیر اجتماعی پایدار یادداشت ها - برخی از مقادیر DR برای CO2، NH3 و آمین های خنثی کننده در فشارهای مختلف - محاسبه نیازهای نرخ تغذیه قلیایی - [جدول اجماع ASME 1: محدودیت های پیشنهادی شیمی آب. لوله آب صنعتی، کارکرد بالا، سوخت اولیه، نوع درام درصد آب آرایشی: تا 100 درصد آب تغذیه. شرایط: شامل سوپرهیتر، درایوهای توربین یا محدودیت فرآیند در خلوص بخار می‌شود] - [جدول اجماع ASME 2: محدودیت‌های پیشنهادی شیمی. لوله آب صنعتی، کارکرد بالا، سوخت اولیه، نوع درام] - [جدول اجماع ASME 3: محدودیت های پیشنهادی شیمی. فایرتیوب صنعتی، کارکرد بالا، سوخت اولیه] - [جدول اجماع ASME 4: حدهای پیشنهادی شیمی آب. مولدهای بخار سریع نوع کویل صنعتی، لوله آب، کارکرد بالا، سوخت اولیه] - [جدول 5 اجماع ASME: محدودیت‌های پیشنهادی شیمی آب. نیروی محرکه دریایی، لوله آبی، نوع درام نفت سوز] - [جدول توافق ASME 6: محدودیت های پیشنهادی شیمی آب. الکترود، ولتاژ بالا، نوع جت گردش اجباری] - یادداشت ها

ادامه ...

Ebook details:
عنوان: Boiler Water Treatment Principles and Practice: Charts and Notes for Field Use
نویسنده: Colin Frayne
ناشر: Chemical Publishing Company (July 3, 2013)
زبان: English
شابک: 082060173X, 978-0820601731
حجم: 1 Mb
فرمت: True Pdf

ادامه ...

ادامه ...
برای ارسال نظر لطفا وارد شوید یا ثبت نام کنید
ادامه ...
پشتیبانی محصول

۱- در صورت داشتن هرگونه مشکلی در پرداخت، لطفا با پشتیبانی تلگرام در ارتباط باشید.

۲- برای خرید محصولات لطفا به شماره محصول و عنوان دقت کنید.

۳- شما می توانید فایلها را روی نرم افزارهای مختلف اجرا کنید(هیچگونه کد یا قفلی روی فایلها وجود ندارد).

۴- بعد از خرید، محصول مورد نظر از صفحه محصول قابل دانلود خواهد بود همچنین به ایمیل شما ارسال می شود.

۵- در صورت وجود هر مشکلی در فرایند خرید با تماس بگیرید.